Dongguan Shengtai Instrument Co., Ltd.
Dongguan Shengtai Instrument Co., Ltd.

Products >> Plastics testing machine >> 

  • Needle Flame Combustion Test Machine
Needle Flame Combustion Test Machine

Needle Flame Combustion Test Machine

 Application:

 

The needle flame tester uses a needle-shaped burner of a specified size (Φ0.9mm), with a specific gas (butane or propane), and directionalally ignites the sample at an angle of 45°, depending on whether the test piece and the ignition bedding layer are ignition and holding time and length of combustion to assess the risk of fire from small flames inside the equipment due to fault conditions.
Needle flame tester is suitable for lighting, low-voltage electrical appliances, household appliances, machine tools, electrical machinery, power tools, electronic instruments, electrical instruments, information technology equipment, electrical affairs equipment, electrical connectors, accessories and other electrical and electronic equipment and components, also suitable for insulating materials, engineering plastics or other solid combustible materials industries.

 

Standards:

 

IEC 60695-2-2: 1991 (Second Edition), Amendment No. 1 of IEC 60695-2-2 (1994-03), IEC60695 -11-5, GB/T 5169.5-2008, GB4706.1-2005 The simulated test project specified by the standard.

 

 

Specifications

 

 

Needle burner

inner hole Φ 0.5mm ± 0.1mm, outer diameter ≤Φ 0.9mm, length ≥ 35mm, stainless steel

Burner angle

tilt 45 ° (test) or vertical (when adjusting the flame height)

Burning time

0-999.9s ± 0.1s adjustable (usually 30s)

Holding time

0-999.9s ± 0.1s, automatic recording, manual suspension

Flame height

12mm ± 1mm (with height measuring instruments)

The gas body

95% butane gas (can use bottled lighter gas)

Temperature test range

0~1000 °C

Flame temperature requirements

from 100 ° C ± 2 ° C to 700 ° C ± 3 ° C time within 23.5 seconds ± 1 second

Temperature thermocouple

Φ0.5mm imported armored (K type) thermocouple

Needle flame burning tester test background

black background

Test process

automatic control of test procedures, independent ventilation

Reference standard

IEC60695 -11-5, GB/T5169.5-2008, GB4706.1-2005

The studio volume

0.5 cubic (can be customized according to customer requirements 0.75 cubic or 1 cubic)

The outer dimensions of the equipment

1000mm wide × 650mm deep × 1300mm high


Contact Us

    Name: Anne Liang

    Tel: +86-13592713824

    E-mail: annelyno@163.com

    WeChat: Annefa1156

    Add: One building, 8 zhuzhong road, Houjie Town, Dongguan City